Smoke hanging over the cooktop? Fan screaming on HIGH? LEDs flicker or die? When a Thermador hood is right, the air clears quickly, the room stays quiet, and the lighting actually helps you cook. If yours roars on HIGH yet leaves a haze over the range, drops into random auto-boost, or eats LEDs, you don’t need a “bigger” hood — you need the right brand-level repair. We service Thermador ventilation the way New York, Los Angeles, Chicago, San Francisco, Houston, and Miami kitchens demand it: same-day when routes allow, building-ready with COI and freight-elevator timing, and with genuine OEM parts on the truck so most fixes land in a single visit. Call 844-975-6696 or book online.

Thermador, Briefly — A Century of Pro Kitchens, Then Smart Ventilation

Since 1916, Thermador has pushed pro-style cooking into homes: early wall ovens, later the open-geometry Star® Burner for full pan coverage, and now Freedom® Induction. Ventilation evolved to match that heat: baffle filter geometry that captures without choking flow, variable-speed maps that keep capture at lower noise, thermal sensors for auto-boost/delay-off, and temperature-rated LED drivers. Under BSH (Bosch/Siemens), control boards gained service modes and tighter protections—great when the duct is right, unforgiving when elbows jam the collar or a non-rated lamp cooks its driver. Translation: airflow + electronics + installation geometry together decide whether your kitchen breathes.

Why Thermador Ventilation Behaves Differently

Thermador matched its pro-heat heritage to ventilation that thinks like a system. Baffle assemblies are designed to catch grease without choking the blower, variable speed maps hold capture at low noise, temperature sensors govern boost and delay-off, and LED drivers are spec’d to survive the thermal envelope above a Pro Harmony® / Pro Grand® range or Freedom® Induction surface.

Since Thermador’s integration into BSH, control boards and service modes got smarter — which is great when everything is in spec and unforgiving when a duct necks down, a damper sticks, or an aftermarket lamp cooks its driver. Translation: airflow, electronics, and installation geometry all share the outcome you feel at the pan.

Real-World Symptoms → External Causes → How We Fix It (Results You Can See)

Haze over the front burners (smoke hangs)

External cause: long/undersized retrofitted ducts, elbows right off the collar, roof caps that backdraft in crosswinds, tight buildings with no make-up air.

What happens: turbulence and backdraft kill capture; blower works harder, noise rises, air stays dirty.
Our fix: measure real CFM at the hood, free/replace the damper, keep one diameter end-to-end (no 6″→8″→6″), rework the first transition, deep-clean/replace saturated baffles, then demonstrate live-flame capture so you see the plume get pulled.

“Jet-engine” drone (loud but not effective)

External cause: crushed flex behind cabinets, step-down transitions out of the hood, resonant rigid runs, negative pressure in airtight homes.

What happens: wheel shakes, vibration amplifies; same airflow produces more noise.

Our fix: true and re-secure the blower, smooth transitions, damp resonant sections, and spec make-up air so the hood isn’t fighting a vacuum.

Fan spins, pull feels weak

External cause: stuck/wind-bound backdraft damper, mixed 6″/8″ sections after remodel, baffles loaded with grease.

What happens: airflow bottlenecks; RPM up, capture down.

Our fix: free/replace damper and cap, ultrasonic-clean or swap baffles, standardize duct diameter, remap speed stages, verify flow at cooking speeds—not just at idle.

Panel acts up (no response, random speeds, ghost touches)

External cause: grease/steam in the keypad, ribbon fatigue from heat, noisy shared circuits, weak neutral/ground in older buildings.

What happens: UI is unpredictable; boost and lights misbehave.

Our fix: install Thermador-spec keypad/ribbon, clean the cavity, verify line/neutral/ground quality, run the board’s service test, stabilize the UI.

Auto-boost wrong time / never engages

External cause: sensor starved by airflow, mapping drift after outages, duct that keeps the probe “too cold” or overheats it.

What happens: boost feels random; delay-off meaningless.

Our fix: test/replace temp sensor, correct the first offsets/elbows so air actually reaches the probe, update mappings where supported, heat-test until behavior matches cooking.

LEDs flicker or die early

External cause: non-rated bulbs from remodels, drivers baking behind lamps, poor thermal contact.

What happens: strobe/flicker, color shift, cooked drivers.

Our fix: fit OEM, temperature-rated LED modules, replace stressed drivers, restore the thermal path, set brightness to illuminate the pan without cooking the electronics.

Grease lines on the backsplash

External cause: baffles reinstalled backwards, hood mounted too high over Star® Burners, front-heavy cooking (wok/steak) with low capture area.

What happens: aerosol leaps past filters and prints on tile/steel.

Our fix: correct baffle orientation, set working height/offset to your range and cabinets, give you a 30-second rinse cadence that keeps capture strong.

Downdraft rises but doesn’t vent / won’t rise

External cause: collapsed flex in the plinth, lift travel out of calibration, control not energizing the blower after a power event.

What happens: unit “moves” but can’t breathe—or won’t rise.

Our fix: recalibrate lift and limits, rebuild with low-loss duct, verify blower outputs at the board, return it rising, venting, and shutting down on command.

Ready to clear the air? Call 844-975-6696 or book onlinesame-day when routes allow; building-ready with COI and freight-elevator timing.

Why Your Kitchen Stays Smoky (only the hits)

  1. House is too tight (no make-up air).
    Hood fights a vacuum; capture collapses.
    Fix: Add a discreet make-up air path and retune speeds—plume bends into baffles again.
  2. Elbow jammed at the collar.
    A 90° right off the hood creates turbulence and stalls flow.
    Fix: Give it 12–18″ of straight run, then the elbow; verify CFM at the collar.
  3. Wind-bound or stuck damper.
    Crosswinds pin the flap; smoke rebounds into the room.
    Fix: Free/replace damper and fit a wind-stable cap; confirm smooth swing and steady draw.
  4. Mounted too high for Star® Burners / front-heavy cooking.
    Wok/sear plumes leap the capture zone, print grease on tile.
    Fix: Set working height/offset to model spec and prove front-burner capture on live flame.
  5. Foil/liners over baffles (or grease-loaded filters).
    Seems “quieter,” actually chokes flow and cooks LED drivers.
    Fix: Remove liners, ultrasonic-clean or replace baffles, restore thermal path to the LEDs.
  6. Keypad ghost touches after cleaning.
    Solvent/moisture in the ribbon = random speeds/lights.
    Fix: Thermador-spec keypad/ribbon, dry & seal the cavity, verify line/neutral/ground.

Seeing one of these? Call 844-975-6696 or book onlinesame-day when routes allow in NYC, LA, Chicago, SF, Houston, and Miami.

What a Visit Feels Like (No Guesswork, No Mess)

We arrive on time with shoe covers, mats, and the paperwork your building wants.

  • The first minutes are measurement and observation — airflow at the collar, noise at working speeds, temperature response at the sensor, voltage and ground quality at the board, and a look at the baffles and duct geometry.
  • You’ll hear a plain-English explanation of what’s happening and why, followed by a written estimate that spells out parts and labor before anything turns a screw.
  • Most repairs complete in one visit because we stock the high-failure items for Thermador hoods — blowers and wheels, backdraft dampers, LED modules and drivers, keypad assemblies and ribbons, temperature sensors, and control boards.
  • When we button up, we repeat the capture and noise checks over real burners, confirm auto-boost and delay-off timing, and leave a short care note so performance doesn’t drift.

Warranty, Parts, and the Boring Stuff That Matters

Repairs use genuine Thermador/OEM components because airflow and electronics are intolerant of knock-offs. You’ll receive a written report with the tests we ran and the numbers we saw, plus a parts-and-labor warranty in writing. If a rare specialty part is required, we expedite it and reserve the first return slot so you aren’t left without ventilation.

Safety First — Ventilation & Building Rules (Quick but Important)

  1. Cut power before service.
    Always switch off the breaker before removing panels or touching wiring/LED drivers.
  2. No foil over filters or intakes.
    Foil and plastic liners choke airflow and overheat the blower and LED drivers.
  3. Use temperature-rated, OEM LEDs.
    Non-rated lamps overheat drivers and flicker early; stick to Thermador-spec modules.
  4. Burning smell = stop now.
    If you smell hot insulation or see smoke, shut the hood down and call for service.
  5. Secure mounting & clearances.
    Verify hood anchors, chimney brackets, and the required stand-off from cabinets.
  6. Check the cord & strain relief.
    No nicks, pinches, or loose strain reliefs that can arc under vibration.
  7. Duct is not optional.
    Never vent into attics/ceilings without a rated duct and cap; moisture + grease = hazard.
  8. Rigid > flex.
    Use rigid metal duct where possible; foil flex is for temporary/short runs only.
  9. One diameter, end-to-end.
    Avoid neck-downs (e.g., 8″→6″) that spike static pressure and noise.
  10. First elbow with space.
    Keep the first elbow 12–18″ from the collar to reduce turbulence.
  11. Damper direction matters.
    Install backdraft dampers in the correct orientation; confirm free movement.
  12. COI & freight-elevator rules.
    High-rises require COI and windowed access; we handle paperwork and timing.
  13. Make-up air in tight homes.
    Airtight construction needs MUA to prevent backdraft, odors, and “jet engine” noise.
  14. Gas range safety.
    If the hood fails during high-BTU cooking and CO alarm sounds, ventilate and stop.
  15. Water and electronics don’t mix.
    Don’t soak keypads or LED bars when cleaning; use a damp cloth, then dry.

Preventive Care That Actually Works

  1. Wash baffles on a schedule. Heavy sear/wok: weekly. Normal cooking: monthly. Reinstall with vanes facing the blower.
  2. Mind the duct path. One diameter end-to-end, rigid metal preferred; keep the first elbow 12–18″ off the collar.
  3. Check damper & exterior cap (seasonal). Free stuck flaps; clear lint/grease/salt so backdraft doesn’t kill capture.
  4. Set the right working height. Too high = weak capture; too low = noise/heat on controls. Match your model spec (Star® Burners / Freedom® Induction).
  5. Replace charcoal on time (recirc). Every 3–6 months or odors come back.
  6. Do the 30-second “plume check.” Boil on a front burner—steam should bend into the baffles on LOW/MED. If not, call.
  7. Use OEM, temp-rated LEDs. Cheap lamps overheat drivers and flicker early.
  8. Plan make-up air in tight homes. Doors slamming when the hood runs = you need MUA for quieter, stronger pull.
  9. Protect the electronics. No solvent sprays on the keypad; avoid overloaded/noisy circuits that trip AFCI/GFCI.

Questions Homeowners Actually Ask (and Straight Answers)

Q: Do I need a bigger hood?

A: Usually no. If the duct path is wrong, a bigger blower just makes more noise. We fix the path, balance the blower, and your existing hood captures more at lower sound.

Q: Why do LEDs keep dying after my reno?

A: Non-rated lamps cook their drivers. We fit Thermador-spec LEDs, replace the driver if stressed, and restore the thermal path so brightness stays stable.

Q: Auto-boost has a mind of its own—can you tame it?

A: Yes. We test the sensor, correct airflow at the probe, update mappings where supported, and heat-test until boost reacts to cooking—not randomness.

Q: We can’t vent outside. Is recirculating worth it?

A: With the right charcoal kit and on-time filter changes, odors drop a lot. We set expectations honestly and give you a change cadence so performance doesn’t fade.

Q: Can this be one visit?

A: Often. We stock common OEM parts. If we need a specialty board or blower, we expedite and slot the first return.

Q: HOA won’t allow exterior venting—can recirculating actually work in my condo?

A: Yes, within limits. We install the correct charcoal kit, set a 3–6 month filter cadence, and tune baffles/height so recirc performance is as good as it gets.

Q: My kitchen is open-plan; hood height vs. Star® Burners—what’s right?

A: We set working height to the model spec and your burner layout. Too high loses capture; too low overheats controls. We prove it with a quick plume check on a front burner.

Q: Wind noise in the duct at night—hood is off but it howls.

A: That’s a cap/damper problem. We fit a quiet, wind-stable cap and verify the damper closes fully. No more midnight whoosh.

Q: Wildfire smoke day (LA/SF): run the hood or not?

A: Run at LOW/MED during cooking only; outside air may be dirtier. Make sure the cap seals when off. For chronic smoke days, we can discuss supplemental filtration.

A Note on Same-Day and Building Access

Our routing is built for cities. In Midtown towers and Brooklyn walk-ups, Westside high-rises and the Chicago Loop, we plan for valet or loading docks, ride the freight elevator within its window, and file the COI your management requires. If your ZIP is near an active route, we often add the stop the same day. You’ll get texts from “arrival window” to “on the way” to “job complete,” so you’re never waiting in the dark.

Same-Day Routes & ZIP Clusters (Add You If You’re Close)

Thermador Repair Services in New York City

Same-day Thermador visits across the five boroughs when routes allow—with COI and service-elevator coordination handled up front. Coverage includes UES/UES, Midtown, FiDi, Williamsburg, Park Slope, LIC/Astoria, Forest Hills (e.g., 10001, 10003, 10019, 10022, 10024, 10065, 11201, 11211, 11215, 11101, 11375). Call 844-975-6696 or book on the New York City page.

Thermador Repair Services in Los Angeles

We run daily citywide routes for prompt Thermador service—Westside to Valley, DTLA to the coast—building-ready and estimate-first. Westwood, Beverly Hills, Santa Monica/Venice, DTLA, Hollywood/Hills, Studio City/Sherman Oaks, Glendale/Pasadena, South Bay, Long Beach, Malibu (e.g., 90024, 90049, 90064, 90066, 90210, 90402, 90403, 90012, 90036, 91604, 91423, 91203, 90277, 90503). Call 844-975-6696 or book on the Los Angeles page.

Thermador Repair Services in Houston

Rapid-response Thermador service across central and suburban Houston, with clear ETAs and OEM parts on the truck. Downtown/EaDo, Montrose/Neartown, The Heights, River Oaks/Upper Kirby, Galleria/Uptown, Memorial/Spring Branch, Bellaire/Meyerland, Clear Lake/Bay Area, Katy, Sugar Land, The Woodlands (e.g., 77002, 77003, 77006, 77019, 77098, 77008, 77056, 77057, 77024, 77079, 77401, 77429, 77494). Call 844-975-6696 or book on the Houston page.

Thermador Repair Services in San Francisco

Same-day availability in SF (as routes open) with condo/HOA coordination and tidy, in-home repairs. SoMa/Mission Bay, Russian/Nob Hill, North Beach/Marina, Pacific Heights, Richmond/Sunset, Mission/Noe/Bernal, Hayes Valley/Haight, Dogpatch/Potrero/Bayview (e.g., 94102, 94103, 94105, 94107, 94158, 94109, 94123, 94115, 94121, 94122, 94110, 94114, 94131, 94124). Call 844-975-6696 or book on the San Francisco page.

Thermador Repair Services in Chicago

Citywide, same-day Thermador slots when released—Loop to lakefront to neighborhoods—transparent pricing and on-site completion. The Loop/River North, Gold Coast/Streeterville, West Loop/Fulton Market, Lincoln Park/Lakeview, Logan Square/Avondale, West Town/Humboldt Park, Hyde Park, Pilsen/Bridgeport (e.g., 60601, 60611, 60654, 60607, 60661, 60614, 60657, 60613, 60647, 60622, 60653). Call 844-975-6696 or book on the Chicago page.

Thermador Repair Services in Miami

Same-day Thermador service throughout Miami-Dade (routes permitting)—COI/vendor forms, service-elevator windows, and beach-bridge timing handled for you. Brickell/Downtown, Coconut Grove, Coral Gables, Edgewater/Design District, Miami Beach, Aventura/Sunny Isles, Doral, Hialeah, Key Biscayne (e.g., 33129, 33130, 33131, 33128, 33132, 33133, 33134, 33146, 33137, 33127, 33139, 33140, 33141, 33160, 33172, 33178, 33012, 33018, 33149). Call 844-975-6696 or book on the Miami page.

Ready to clear the air? Call 844-975-6696 or book online. We’ll restore capture, quiet the cabinet, and make the controls behave—today, if the route allows.